A
A.1
Parameter list
A-842
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1615
Tolerance rotational accuracy monitor
Min
Standard
Max
Unit
Data type
Effective
0.0
0.2
100.0
m/min
Floating Point
immed. (SLM)
0.0
2.0
100.0
rpm
Floating Point
immed. (SRM ARM)
Note: Internal Siemens
1616
Diagnosis, actual speed value
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
When continuously increased by several increments, there is an increased noise level (the
speed actual value is faulty).
1620
Bits for variable signaling function
Min
Standard
Max
Unit
Data type
Effective
0
0
7
Hex
Unsigned16
immed.
... defines the behavior of variable message function.
Bit 0
Variable message function
Bit 0 = 1
Active
Bit 0 = 0
Inactive
Bit 1
Segment, variable message function
Bit 1 = 1
Address space Y
Bit 1 = 0
Address space X
Bit 2
Comparison, signed
Bit 2 = 1
Comparison with sign
Bit 2 = 0
Comparison without sign
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1621
Signal number, variable signaling function
Min
Standard
Max
Unit
Data type
Effective
0
0
530
–
Unsigned16
immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1622
Address, variable signaling function
Min
Standard
Max
Unit
Data type
Effective
0
0
FFFFFF
Hex
Unsigned32
immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1623
Threshold, variable signaling function
Min
Standard
Max
Unit
Data type
Effective
FF000001
0
FFFFFF
Hex
Integer32
immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
A Lists
01.99
! 611ue diff !
04.05