5
5.6
Net data (PKW and PZD area)
5-232
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Data transfer format: Units as for parameter P0081:64 in MSR
Limits:
min: –200000000 MSR
max: 200000000 MSR
For MDI blocks, the speed is transferred via this control word.
MDIVel
Transfer format:Units as for parameter P0082:64 in c*MSR/min
Limits
min: 1000 c*MSR/min
max: 2000000000 c*MSR/min
For MDI blocks, the acceleration override is transferred via this control
word.
MDIAcc
Data transfer format: Units as for parameter P0083:64 in %
Limits:
min: 1 %
max: 100 %
For MDI blocks, the deceleration override is transferred via the control
word.
MDIDec
Data transfer format: Units as for parameter P0084:64 in %
Limits:
min: 1 %
max: 100 %
For MDI blocks, the mode is transferred via this control word.
MDIMode
Data transfer format: Units as for parameter P0087:64 in Hex
The following ID is only active for MDI:
x0x = ABSOLUTE
x1x = RELATIVE
x2x = ABS_POS
x3x = ABS_NEG
0xx = END
3xx = CONTINUE EXTERNAL
Control word
MDIVel
(pos mode)
(from SW 7.1)
Control word
MDIAcc
(pos mode)
(from SW 7.1)
Control word
MDIDec
(pos mode)
(from SW 7.1)
Control word
MDIMode
(pos mode)
(from SW 7.1)
5 Communications via PROFIBUS DP
08.99