6
6.4
Input/output terminals of the control board
6-500
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.4.6
List of output signals
Reader’s note
The drive ”signals” the output signals, listed in the Tables 6-48 and
6-49 either through an output terminal or as status bit to
PROFIBUS–DP.
All of the output signals can be found in the Index under Output
signal... .
For output signals, which are assigned to terminals, an inversion can
be parameterized. In this list, these output signals are represented as
not inverted.
If an output signal inversion has been parameterized, then this must be
appropriately taken into account when representing the signal.
The following must be specified for each signal:
Fct. No.:
The function number is required to parameterize the output terminal
via the display and operator control unit.
Operating mode (P0700):
This specifies in which operating mode the signal is available
(x: Available, –: Not available).
n–set:
”Speed/torque setpoint” mode
pos: ”Positioning”
mode
PROFIBUS bit:
The bit name is required to read the signal via PROFIBUS–DP
(refer to Chapter 5.6.1).
Example: ZSW2.10
––> that means, status 2 bit 10
6 Description of the Functions
01.99
! 611ue diff !
08.01