A
A.1
Parameter list
A-765
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0658
Image, output signals, Part 3
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned32
RO
... is an image of selected output signals (terminal and PROFIBUS signals).
Bit 0
Ramp-up completed
Bit 1
|M| < M_x (P1428:8, P1429)
Bit 2
|n_act| < n_min (P1418:8)
Bit 3
|n_act| < n_x (P1417:8)
Bit 4
V_DC link < V_x (P1604)
Bit 5
Variable signaling function
Bit 6
Motor temperature alarm (P1602)
Bit 7
Heatsink temperature pre-alarm
Bit 8
n_set = n_act (P1426, P1427)
Bit 9
Fixed end stop reached
Bit 10 Fixed end stop, clamping torque reached
Bit 11 Traverse to fixed endstop active
Bit 12 Tracking mode active
Bit 13 Velocity limiting active
Bit 14 Setpoint is zero
Bit 15 Synchronized
Bit 16 Axis moves forwards
Bit 17 Axis moves backwards
Bit 18 Minus software limit switch actuated
Bit 19 Plus software limit switch actuated
Bit 20 Cam switching signal 1
Bit 21 Cam switching signal 2
Bit 22 Direct output 1 via traversing block
Bit 23 Direct output 2 via traversing block
Bit 25 Power module current not limited
Bit 28 Pulses enabled
Bit 29 Position reached
Bit 30 Spindle position 2 reached
Bit 31 Teach In executed
0659
Bootstrap loading
Min
Standard
Max
Unit
Data type
Effective
0
0
4
–
Unsigned16
PO
... it is possible to toggle between the initialization and normal condition.
0
Establish initialized condition
0 –> 1 Initialize
1
Normal condition
2, 3, 4 Internal Siemens
Note:
Only the most important parameters can be selected and changed (e.g. motor code, power sec-
tion code) in the initialized condition.
In the normal condition, the motor code and power section code are write-protected.
When starting-up for the first time using ”Load file”, P0659 remains at 2 (internal siemens).
A Lists
01.99
! 611ue diff !
04.05