5
5.10 Slave–to–slave communications (from SW 4.1)
5-326
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters have been set:
P0922 = 109
––> Standard telegram 109: Slave drive for the position reference
value coupling
P0891 = 4
––> Source for ”External position reference value”: PROFIBUS–DP
Normalization using P0895 and P0896
Setting for the best possible resolution:
P0895 = 2048 increments
P0896 = 5 MSR
P0896
2
31
P0895
Max. traversing distance which
can be represented:
Optional: Inverting the external position reference value using
P0897
Fig. 5-39 Parameterization, slave drive
Parameterization,
slave drive
5 Communications via PROFIBUS DP
08.99
07.01
08.01