Operating mode, speed/torque setpoint (P0700 = 1)
6-337
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-2
Parameters for the speed controller optimization
Parameters
No.
Name
Min.
Stan-
dard
Max.
Units
Effec-
tive
1407:8
P gain, speed controller (SRM, ARM)
P gain, velocity controller (SLM)
0.0
0.3
2 000.0
999 999.0
Nm*s/rad
Ns/m
Imme-
diately
... specifies the magnitude of the proportional (gain K
p
, proportional component) of the control
loop.
1409:8
Integral action time, speed controller (SRM,
ARM)
Integral action time, velocity controller (SLM)
0.0
10.0
500.0
ms
Imme-
diately
... specifies the integral action time (T
N
, integral component) of the control loop.
Reader’s note
When optimizing, e.g. linear drives, it may be necessary to set the
current and speed setpoint filters.
This procedure is described in: