6
6.7
Analog outputs
6-545
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-55
Parameter overview for the analog outputs, continued
Terminals
Parameters
No.
Ef-
fec-
tive
Units
Max.
Stan-
dard
Min.
Name
No.
Desig-
nation
–
–
0624
Signal
No. 35
DAU normalization, motor utiliza-
tion
–200.0
100.0
200.0
%
Im-
medi-
ately
... defines, for the output of ”utilization (M
set
/M
set, limit
, finely normalized” (Signal
No. 35) which voltage is obtained when
|maximum torque| (at n = 0 to n
rated
)
|power| (at n > n
rated
).
is reached.
Examples:
P0624 = 100 % –> +10 V
Max. torque or power
P0624 = 50 % –> +5 V
Max. torque or power
–
–
0625
Signal
No. 36
D/A normalization, torque setpoint
(SRM, ARM)
D/A normalization, force setpoint
(SLM)
–200.0
100.0
200.0
%
Im-
medi-
ately
... defines for the output of ”torque setpoint, finely normalized” (Signal No. 36),
which voltage is output when 200% rated torque is reached.
Examples:
P0625 = 100 % –> +10 V
twice the rated torque
P0625 = 50 % –> +5 V
twice the rated torque
Note:
The output of signal No. 36 is signed.
6 Description of the Functions
01.99