A
A.1
Parameter list
A-834
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1466
Changeover speed, open-loop/closed-loop control IM (ARM)
Min
Standard
Max
Unit
Data type
Effective
150.0
300.0
100000.0
rpm
Floating Point
immed. (ARM)
Threshold speed for changing over between closed-loop and open-loop control for induction
motor operation.
1490
Activate equalization controller
(–> 7.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
2
–
Unsigned16
PO
...can activate the anti-backlash controller (equalization controller).
0
no source or no equalization controller
1
active, source is terminal 24/20
2
active, source is the adjacent drive (double-axis module)
1491
P gain equalization controller
(–> 7.1)
Min
Standard
Max
Unit
Data type
Effective
0.0
0.1
10000.0
rad/s/Nm
Floating Point
immed.
1492
Integral action time equalization controller
(–> 7.1)
Min
Standard
Max
Unit
Data type
Effective
0.0
20.0
8000.0
ms
Floating Point
immed. (ARM)
0.0
10.0
8000.0
ms
Floating Point
immed. (SRM SLM)
1493
Pre-tensioning torque, equaliz. controller (ARM SRM)
(–> 7.1)
Pre-tensioning force, equalization controller (SLM)
Min
Standard
Max
Unit
Data type
Effective
–200.0
0.0
200.0
N
Floating Point
PO
(SLM)
–200.0
0.0
200.0
Nm
Floating Point
PO
(SRM ARM)
... enters a pre-tension torque (or pre-tension force (SLM)) which acts with switc
h-
in delay via a
PT1 element (P1494)
1494
Time const., pre-tens. torque, equal. cntr. (ARM SRM)
(–> 7.1)
Time constant, pre-tensioning force, equalization contr. (SLM)
Min
Standard
Max
Unit
Data type
Effective
1.0
1.0
1000.0
ms
Floating Point
immed.
... enters the time constant for the PT1 element which ensures a soft, gentle increase of the
pre-tensioning torque (P1493) when activating the equalization controller.
1495
Torque weighting, equaliz. contr. – master (ARM SRM) (–> 7.1)
Force weighting equalization controller – master (SLM)
Min
Standard
Max
Unit
Data type
Effective
–100.0
100.0
100.0
%
Floating Point
immed.
... enters a weighting for the torque setpoint ( or force for the force setpoint (SLM) ) of the
master axis for the equalization controller.
1496
Torque weighting, equaliz. contr. – slave (ARM SRM)
(–> 7.1)
Force weighting equalization controller – slave (SLM)
Min
Standard
Max
Unit
Data type
Effective
0
100.0
100.0
%
Floating Point
immed.
... enters a weighting fo the torque setpoint ( or force for the force setpoint (SLM) ) of the slave
axis for the equalization controller.
A Lists
01.99
! 611ue diff !
04.05