A
A.1
Parameter list
A-776
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0872
Option module type
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
... displays which option module was identified when the control module was powered-up.
0
no option module
1
Optional TERMINAL module, Order No. (MLFB): 6SN1114–0NA00–0AA0
2
Option module PROFIBUS-DP1
with PROFIBUS-ASIC SPC3, Order No. (MLFB): 6SN1114–0NB00–0AA0
3
Option module PROFIBUS-DP2 (from SW 3.1)
with PROFIBUS ASIC DPC31 without PLL, Order No. (MLFB): 6SN1114–0NB00–0AA1
4
Option module PROFIBUS-DP3 (from SW 3.1)
with PROFIBUS ASIC DPC31 with PLL, Order No. (MLFB): 6SN1114–0NB01–0AA0
253
CAN – option module, Robox company
255
Third-party module corresponding to the published interface spec. (from SW 4.1)
0873
Option module version
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... displays the version of the respective option module.
0875
Expected option module type
Min
Standard
Max
Unit
Data type
Effective
0
0
255
–
Unsigned16
PO
... displays which option module is expected due to the parameters set.
During first startup, the parameter is automatically set according to P0872 (option module type).
Note:
Disable the communication or the ”DP slave 611U”:
1-axis module
––> with P0875 = 0 from drive A, the ”DP slave 611U” is disabled
2-axis module
––> with P0875 = 0 from drive B, communication with drive B is disabled
––> with P0875 = 0 in both drives, the ”DP slave 611U” is disabled
This allows, for example, ”disturbing” slaves to be temporarily disabled when commissioning
other nodes (refer to the index entry ”Commissioning PROFIBUS-DP”).
A Lists
01.99
! 611ue diff !
04.05