6.11 Motor changeover for induction motors (from SW 2.4)
6-588
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.11.3
Changeover, 1 motor with max. 4 data sets (P1013 = 2)
For this changeover version (P1013 = 2) for one motor, a maximum of
4 motor data sets can be changed over.
Note
The pulses are not canceled at changeover, i.e. the changeover is
made with the pulses enabled.
This version can be used to adapt the motor and controller data.
The following input/output signals are used for this changeover version:
Table 6-63
Input/output terminal signals
Input terminal
with
function No.
Effective
motor data set
Output terminal
with
function No.
6
5
14
1)
13
1)
12
1)
11
1)
0
0
P1xxx
0
0
0
0
0
1
P2xxx
0
0
0
0
1
0
P3xxx
0
0
0
0
1
1
P4xxx
0
0
0
0
1) The output terminals with function numbers 11 to 14 are not energized.