7
7.6
Spare parts
7-730
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
7.5.3
Parameters for V/Hz operation
The following parameters are available for V/Hz operation
Table 7-10
Parameter overview for V/Hz operation
Parameters
No.
Name
Min.
Stan-
dard
Max.
Units
Effec-
tive
1014
Activates V/Hz operation
0
0
1
–
PO
... V/Hz operation for this drive is activated/de–activated.
= 1
V/Hz operation is activated
= 0
V/Hz operation is de–activated
1125
Ramp–up time 1 for V/Hz operation
0.01
5.0
100.0
s
Imme-
diately
When V/Hz operation is activated, this is the time in which the speed setpoint is changed from
0 to the maximum motor speed (P1146).
1127
Voltage at f = 0 V/Hz operation (ARM)
0.0
2.0
20.0
V(pk)
Imme-
diately
When V/Hz operation is activated, and at 0 frequency, the voltage which is output is increased
by the value in this parameter.
Note:
The parameter is preset when carrying–out the ”calculate controller data” function.
7.6
Spare parts
Table 7-11
Terminals for SIMODRIVE 611 universal
Designation
Terminals
Item number
Order No.
[MLFB]
X421
AS1, AS2
GWE–000000590513
6SY9907
X431
P24, M24,9 663,19
GWE–000000588343
6SY9908
X451, X452
56.x, 14.x, 24.x, 20.x, ...
GWE–000000588293
6SY9910
X461, X462 (10 pin)
A+.x, A–.x, B+.x, B–.x
X461, X462 (11 pin)
A+.x, A–.x, B+.x, B–.x
A5E0009717
6SY9913
X453, X454
A+.x, A–.x, B+.x, ...0
X441
75.x. 16.x, 15
GWE–000000588277
6SY9911
X422, X432
I4...I11, O4...O11
GWE–000000588285
6SY9912
Power connector, motor connec-
tion
6SY9904
Power connector, pulsed resistor
6SY9905
Parameter
overview
7 Fault Handling/Diagnostics
01.99
08.02