A
A.1
Parameter list
A-824
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1220:8
Bandwidth, current setp. filter 4
Min
Standard
Max
Unit
Data type
Effective
5.0
500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1221:8
Numerator, bandwidth current setpoint filter 4
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1222:8
BSF natural frequency, current setpoint filter 1
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
1.0
100.0
100.0
%
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1223:8
BSF natural frequency, current setpoint filter 2
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
1.0
100.0
100.0
%
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1224:8
BSF natural frequency, current setpoint filter 3
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
1.0
100.0
100.0
%
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1225:8
BSF natural frequency, current setpoint filter 4
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
1.0
100.0
100.0
%
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1230:8
1st torque limit value (ARM SRM)
1st force limit value (SLM)
Min
Standard
Max
Unit
Data type
Effective
5.0
100.0
900.0
%
Floating Point
immed.
The parameter value refers to the stall torque (SRM), rated motor torque (ARM) and stall force
(SLM) of the motor.
Note: refer to the index entry ”Limits”
1233:8
Generative limitation
Min
Standard
Max
Unit
Data type
Effective
5.0
100.0
100.0
%
Floating Point
immed.
The setting refers to the parameter value in P1230.
A Lists
01.99
! 611ue diff !
04.05