6
6.3
Axis couplings (from SW 3.3)
6-433
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-39
Overview: Position reference value interface
Features
Description
Can be switched–in/out
Activated via input signal ”activate coupling” and ”activate coupling via
I0.x” or PROFIBUS bit PosStw.4
P0410 = 1
Speed–synchronous
P0410 = 2
Position–synchronous
P0410 = 7
To the absolute position of the master drive from + P0412
(from SW 4.1)
via a traversing block with the COUPLING_IN or COUPLING_OUT com-
mand
P0410 = 3
Speed–synchronous
P0410 = 4
Position–synchronous
P0410 = 8
To the absolute position of the master drive from + P0412
(from SW 4.1)
via the traversing block with the COUPLING_IN or COUPLING_OUT
command and queue functionality (being prepared)
P0410 = 5
Speed–synchronous
P0410 = 6
Position synch P0412
Superimposed motion
Yes, via traversing blocks with the coupling switched–in
Autonomous motion
Yes, via traversing blocks with the coupling switched–out
Possible position refer-
ence value source
Angular incremental encoder interface switched as input
Drive A (for an internal coupling)
PROFIBUS–DP master (from SW 4.1)
PROFIBUS–DP slave (slave–to–slave communications) (from SW 4.1)
Parameterize the angular
incremental encoder in-
terface as output
P0892
Factor, angular incr. enc. pulse no./enc. pulse no.
P0893
Angular incremental encoder zero pulse offset
––> Refer to Chapter 6.8.1
terface as output
P0890 = 1
Output pos. actual values
––> Refer to Chapter 6.8.1
Parameterize the angular
incremental encoder in-
terface as input
P0890 = 2
Receive position refer-
P0891
Source, external position reference value
P0894
Angular incremental encoder input signal waveform
P0895
External position reference value – No. of increments
P0896
Ext. position reference value – No. of dimension
system grids
Receive position refer-
ence values
system grids
P0897
Inversion, external position reference value
P0401
Coupling factor, revolutions master drive
P0402
Coupling factor, revolutions slave drive
––> Refer to Chapter 6.8.2
Parameterize PROFIBUS
interface as input
P0891
Source, external position reference value
P0895
External position reference value – No. of increments
P0896
Ext. position reference value – No. of dimension
system grids
P0897
Inversion, external position reference value
system grids
P0897
Inversion, external position reference value
P0898
Modulo range, master drive
P0401
Coupling factor, revolutions master drive
P0402
Coupling factor, revolutions slave drive
Referencing for incre-
mental measuring sys-
tems
Required, if autonomous or superimposed motion has to be executed via
traversing blocks
––> Refer to Chapter 6.2.4
Available in the operating
mode
”Positioning” (P0700 = 3)
6 Description of the Functions
01.99
08.01