General commissioning information
4-118
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The units are designed for the specified mechanical, climatic and
electrical ambient conditions. None of the limit values may be ex-
ceeded in operation nor during transport. Please pay special atten-
tion to the following:
– Line supply conditions
– Pollutants
– Damaging gases
– Climatic ambient conditions
– Storage/transport
– Shock stressing
– Vibration stressing
– Ambient temperature
– Total (summed) current of the digital outputs (refer to Chap. 2.3)
Reader’s note
More detailed information on the drive group and the ambient
conditions is provided in:
Reference:
/PJU/
SIMODRIVE 611
Configuration Manual, Drive Converters
!
Caution
Generally, the following is valid: Before powering–up or down using the
main switch or a line contactor, terminal 63 (pulse enable) and/or
terminal 48 (start terminal, contactor control) must be de–energized or
disconnected at the supply infeed module (NE module!
Otherwise, there is a danger that the line supply infeed module
will be destroyed.
In order that the optional PROFIBUS module can be upgraded error–
free, the cyclic PROFIBUS connection must interrupted. In this case,
the physical connection must also be interrupted, i.e. the PROFIBUS
connector must be withdrawn.
The firmware cannot be upgraded while data is being transferred via
the PROFIBUS.
Note
If the firmware is updated via PROFIBUS–DP and is then interrupted,
the firmware can only be downloaded via the serial link. This is the
case for the existing software releases
SW 4.1 or
SW 7.2.
Upgrading the
firmware of the
optional
PROFIBUS module
4 Commissioning