background image

INSTALLATION

 

INSTRUCTIONS

 

VOLUME 3

 

REFERENCE DOCUMENTATION

 

© NAPCO 2021

 

WI1653GLF Vol 3  9/21

 

COMMERCIAL / RESIDENTIAL 

 

GEMC

-

255

 

GEMC

-

128

 

GEMC

-

96

 

GEMC

-

32

 

 

CONTROL PANEL / COMMUNICATOR

 

Installing the GEMINI C

-

Series Control Panels with the 

 

GEMC

-

FK1

 Keypad and the 

GEMC

-

BK1 

Keypad

 

WIRELESS

 

HARDWIRE

 

GEMC

-

FK1 Keypad

 

GEMC

-

BK1 Keypad

 

SYSTEM READY 
11/02/28

                         

12:05 AM 

SYSTEM NORMAL 

11/02/28

                         

12:05 AM 

Publicly traded on NASDAQ     Symbol: NSSC

 

Содержание GEMINI C Series

Страница 1: ...IAL GEMC 255 GEMC 128 GEMC 96 GEMC 32 CONTROL PANEL COMMUNICATOR Installing the GEMINI C Series Control Panels with the GEMC FK1 Keypad and the GEMC BK1 Keypad WIRELESS HARDWIRE GEMC FK1 Keypad GEMC B...

Страница 2: ...ws are registered trademarks of the Microsoft Corporation All other trademarks cited in this manual are for reference only and are the property of their respective owners Copyright 2021 by NAPCO Secur...

Страница 3: ...rammable Output Module 6 GEMC RECV Wireless RF Receiver 6 GEMC NACXX Supervised NAC Extender 6 GEMC FPRINT Parallel Printer Interface 6 GEMC 12V2APS CF Power Supply 6 GEMC 12V2APS R Power Supply 7 Fir...

Страница 4: ...ent 25mA plus GEMC F8ZCPIM total standby and alarm current Maximum Total Combined 24V Standby Total combined 12V standby plus alarm current times 0 6 NAC A D 24V standby cur rent plus GEMC BM total co...

Страница 5: ...ent must be reduced by GEMC BSLC current Operating Temperature 32 to 120 F 0 to 49 C Dimensions W x D x H 4 5 x 4 x 1 Modules Mounted Inside the C Series Motherboard Enclosure GEMC NL MOD Network Comm...

Страница 6: ...outputs are 24V Regulated Supervision AC fail supervision approximate 1 minute delay to prevent nui sance swingers Battery presence low battery supervision and battery charger volt age supervision com...

Страница 7: ...re Set Point 40 F 4 RATINGS Electrical Ratings Input Power 13 6 16 3VDC supplied by GEMC BSLC module 19mA Output Power not applicable Maximum Wiring Length 2000 feet 16 AWG Refer to GEMC BSLC document...

Страница 8: ...Glass types minimum size 10 7 8 x 10 7 8 280 mm x 280 mm 3 32 3 8 plate 1 8 3 8 tempered 1 8 9 16 laminated 1 4 wired 5 8 overall sealed insulated Note Coated glass with security films including film...

Страница 9: ...put Maximum charge current 1 96A 4 ampere continuous supply current at 24VDC Built in charger for sealed lead acid or gel type bat teries Automatic switch over to stand by battery when AC fails AC inp...

Страница 10: ...t Entry Trouble 55 R370 Burg Exit Entry Trouble Restore 56 E137 Burg Zone Tamper Alarm 57 R137 Burg Zone Tamper Restore 58 E370 Burg Zone Tamper Trouble 59 R370 Burg Zone Tamper Trouble Restore 60 E40...

Страница 11: ...Disable Restore 187 E342 Fire Monitor AC Fail 188 R342 Fire Monitor AC Fail Restore 189 E342 Fire Monitor AC Fail Trouble 190 R342 Fire Monitor AC Fail Trouble Restore 191 E338 Fire Monitor Bat Test...

Страница 12: ...CPIM Conventional 8 Fire Zone Expander Plug in Module see WI1651 GEMC FK1 Fire keypad see WI1649 OI341 GEMC FPRINT Print module for Fire Bus see WI1708 GEMC FW SLC Fire SLC Module see WI1647 GEMC HSKI...

Страница 13: ...ystem Kit As above but with 24V Panel 128 Points via commercial addressable wire less or conventional fire devices 4 on board NACs provid ing up to 6 5A notification power GEMC FW 32KT 32 Point GEM C...

Страница 14: ...ogy Motion Detector PIR and Microwave Range 40 x40 Fire Peripherals GEMC FK1 LCD Fire Keypad for GEMC Combo System Red GEMC WL SMK Wireless Commercial Fire Device Photoelectric Smoke De tector GEMC WL...

Страница 15: ...EMC NAC7S Remote NAC Extender Provides four 4 NAC Outputs for a combined output rating of 6 5A or a maximum of 2A on any one output Includes red enclosure 14 x16 must be connected to 120VAC source sup...

Страница 16: ...e system design is possible These Worksheets have been placed into a single Microsoft Excel file available online at the NAPCO website http www napcosecurity com Once at the NAPCO website click the li...

Страница 17: ...r lights indicating the Burglary Access Control portion of the sys tem is disabled 3 If the GEMC BM GEMC BM PS or GEMC BSLC module s are used The general idea is to unplug each of these Burglary modul...

Страница 18: ...B 7 NAC C 9 NAC D 14V 8V pulsing when active 21 REMOTE BUS YEL 20 REMOTE BUS GRN 10V 2 NAC A 4 NAC B 6 NAC C 8 NAC D Zero 0 Volts 3 NAC A 5 NAC B 7 NAC C 9 NAC D 19 REM PWR 23 AUX PWR 2 or 4 GEMC FW...

Страница 19: ...erences the Micro number either Micro 1 or Micro 2 for example ComboMicro1 hex Therefore for the Micro number referenced in the file name click the appro priate Browse button within either the Micro 1...

Страница 20: ...ower supervise the power with an end of line relay as shown below Connect the EOL relay to a conventional or SLC zone programmed as a Fire Monitor Zone Zone Programmed as Fire Monitor Zone POWER IN PO...

Страница 21: ...NAPCO Gemini C Series Control Panel Installation Instructions Volume 3 Installation Instructions Volume 3 Page 21 NOTES...

Страница 22: ...NAPCO Gemini C Series Control Panel Installation Instructions Volume 3 Page 22 Installation Instructions Volume 3 NOTES...

Страница 23: ...ons Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 CAUTION...

Страница 24: ...paired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or remove...

Отзывы: