6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-408
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.2.10
Programming traversing blocks
A maximum of 64 traversing blocks can be programmed. The informa-
tion associated with each block is listed in the following table:
Table 6-36
Overview of the traversing blocks
Block
memory...
Description
Description
Memory
80:0
80:1
...
Block number
A traversing block must be assigned a block number between 0 and 63,
so that it becomes valid and can be started.
...
80:63
81:0
81:1
...
Item
Specifies the target position in the block to be approached.
...
81:63
82:0
82:1
...
Velocity
Specifies the velocity with which the target position is approached.
...
82:63
83:0
83:1
...
Acceleration override
This allows the acceleration to be influenced, referred to P0103.
...
83:63
84:0
84:1
...
Deceleration override
This allows the deceleration to be influenced, referred to P0104.
...
84:63
85:0
85:1
...
Command
Each traversing block must contain a command (refer to Table 6-37).
1
POSITIONING (Standard)
+: Block number, position, velocity,
Acceleration override, deceleration override, mode
2/3
ENDLESS TRAVERSING_POS/ENDLESS TRAVERSING_NEG
+: Block
number,
velocity,
Acceleration override, deceleration override, mode
4
WAIT
+: Block number, delay time in the ”command parameter”, mode
5
GOTO
+: Block no., target block no. in the ”command parameter”, mode
6/7
SET_O/RESET_O
+: Block number, output No. in the ”command parameter”, mode
8
FIXED ENDSTOP (from SW 3.3)
+: Block number, position, velocity,
Acceleration override, deceleration override,
Value range and units for clamping torque/clamping force in
the ”Command parameter”, mode
9/10
COUPLING_IN/COUPLING_OUT (from SW 3.3)
+: Block
number,
mode
...
85:63
86:0
86:1
...
Command parameters
Additionally required information to execute the command is specified
here.
...
86:63
Overview
6 Description of the Functions
01.99
! not 611ue !
08.02