6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-422
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
In this case, a new traversing block is only started if the previous block
had been completed, i.e. the drive has reached the reference position.
Activate
traversing task
(positive edge!)
Setpoint
acknowledge
Reference
position
reached
Drive at
standstill
1
2
3
0
1
2
Block
selection
0
1
2
Block selection
(checkback
signal)
OC/reject
traversing task
OC/
intermediate
stop
Control
signal
Control
signal
Control
signals
Status signals
Control signal
Status signal
Status signal
Status signal
1
Selecting and starting the first traversing block
––> selected via ”block selection”
––> edge of ”activate traversing task” ––> ”setpoint acknowledgment” is set to a ”1” signal.
2
End of the first positioning operation,
––> ”setpoint acknowledgment” is reset
––> ”reference position reached” is set if the actual position is within the defined window
––> ”drive stationary” is set, if the speed is less than the speed limit for ”drive stationary”
The second traversing block is started
3
End of the second positioning operation
Fig. 6-25 Sequentially starting individual blocks
Note
The selection and the status of the block selection are not
binary–coded, but represented, simplified as value.
Example:
Sequential start of
individual blocks
6 Description of the Functions
01.99