A
A.1
Parameter list
A-755
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0599
Active motor data set
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
... displays whether the motor changeover has been enabled, and which motor data set is active.
0
Motor changeover inhibited (P1013 = 0)
1
Motor data set 1 (P1xxx) active
2
Motor data set 2 (P2xxx) active
3
Motor data set 3 (P3xxx) active
4
Motor data set 4 (P4xxx) active
Note: refer to the index entry ”Motor changeover”
0600
Operating display
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned32
RO
... displays the actual operating status of the unit.
Note:
refer to the index entry ”Operating display” for the significance of the segments on the display
unit.
0601
Motor speed setpoint (ARM SRM)
Velocity setpoint, motor (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
m/min
Floating Point
RO
(SLM)
–
–
–
rpm
Floating Point
RO
(SRM ARM)
... is used to display the unfiltered summed setpoint for speed or velocity of the motor.
0602
Actual motor speed (ARM SRM)
Velocity actual value, motor (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
m/min
Floating Point
RO
(SLM)
–
–
–
rpm
Floating Point
RO
(SRM ARM)
... is used to display the unfiltered actual value for speed or velocity of the motor.
0603
Motor temperature
Min
Standard
Max
Unit
Data type
Effective
–
–
–
C
Integer16
RO
... displays the motor temperature measured via the temperature sensor.
Note:
The display is invalid if a fixed temperature was entered in P1608.
0604
Utilization, motor
Min
Standard
Max
Unit
Data type
Effective
–
–
–
%
Floating Point
RO
This parameter is used to display the motor utilization.
The ratio between the ”Torque setpoint M” and ”Actual torque limit Mmax” or
”Force setpoint F” and ”Actual force limit Fmax” is displayed.
Values of less than 100% indicate the system reserve.
Note:
The motor utilization display is smoothed using a PT1 filter (P1251).
0606
Voltage at term. 56.x/14.x
Min
Standard
Max
Unit
Data type
Effective
–
–
–
V(pk)
Floating Point
RO
... displays the analog voltage presently available at this input terminal.
A Lists
01.99
! 611ue diff !
04.05