A
A.1
Parameter list
A-751
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0238:8
Load revolutions
Min
Standard
Max
Unit
Data type
Effective
1
1
8388607
–
Unsigned32
PO
... specifies the ratio (Ü) between the encoder and load.
Ü = P0237:8 / P0238:8
Note: refer to the index entry ”Encoder adaptation”
0239
Re-reference or re-adjust only if necessary
(–> 4.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
immed.
0
Referencing or adjustment is withdrawn when changing the parameter set (standard)
1
Referencing or adjustment is only withdrawn when the parameter set is changed if the
mechanical ratio (Ü = P0237:8 / P0238:8) changes.
Note: refer under the index entry ”Referencing or adjustment”
0241
Activating, modulo conversion, rotary axis (SRM ARM) (–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
PO
(SRM ARM)
1
Modulo conversion activated, modulo correction is executed according to P0242
0
Modulo conversion de-activated
Note:
refer to the index entry ”rotary axis with modulo offset”
0242
Modulo range, rotary axis (SRM ARM)
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
1
360000
100000000
MSR
Unsigned32
PO
(SRM ARM)
... defines the modulo range of the rotary axis.
Practical modulo range values are: n * 360 degrees with n = 1, 2, ...
Note:
refer to the index entry ”rotary axis with modulo offset”
0250
Activate direct measuring system (SRM ARM)
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
PO
(SRM ARM)
... the direct measuring system at X412 is activated/deactivated for drive A.
1
Direct measuring system activated (only drive A)
0
Direct measuring system deactivated
Note:
refer to the index entry ”Direct measuring system”
0310
Cam switching position 1
Min
Standard
Max
Unit
Data type
Effective
–200000000
0
200000000
MSR
Integer32
immed.
... the cam switching position 1 is set.
Note: refer to the index entry ”Position-related switching signals (cams)”
0311
Cam switching position 2
Min
Standard
Max
Unit
Data type
Effective
–200000000
0
200000000
MSR
Integer32
immed.
... the cam switching position 2 is set.
Note: refer to the index entry ”Position-related switching signals (cams)”
A Lists
01.99
! 611ue diff !
04.05