A
A.1
Parameter list
A-744
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0124
Teach-in configuration
(–> 4.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
3
Hex
Unsigned16
immed.
... specifies in which mode teach in is executed.
Bit 0
Automatic block change enable
In this mode, after each successful ”teach-in”, the teach-in block in P0120 is automatically in-
creased.
Bit 0 = 1
On
Bit 0 = 0
Off
Bit 1
Automatic block search
In this mode at ”teach-in” a search is made for the block in P0120.
Bit 1 = 1
On
The block, entered in P0120 or the block selected via the input signals, is re-generated.
Bit 1 = 0
Off
A fault is initiated if the block in P0120 or the block selected via the input signals is not avail-
able.
Note:
refer under the index entry ”Teach-in”
0125
Spindle positioning active
(–> 5.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
2
–
Unsigned16
PO
... switches the ”spindle positioning” function into the mode ”n-set” on/off.
0
De-activate spindle positioning
1
Activate spindle positioning
Note:
refer under the index entry ”Spindle positioning”
0126
Spindle positioning, zero mark tol. window (BERO)
(–> 5.1)
Min
Standard
Max
Unit
Data type
Effective
0
7200
360000
MSR
Unsigned32
immed.
... specifies the zero tolerance window in degrees, which is monitored by the spindle position-
ing, in order to secure, in conjunction with a BERO, the zero mark consistency. If the zero mark
is not recognized, or if uneven zero mark clearances are measured which are outside the toler-
ance, then alarm message 186 or 193 is output, e.g. if the encoder cable is, for example, inter-
rupted.
0
De-activate zero mark monitoring
>0
Zero mark monitoring is activated
Note:
refer under the index entry ”Spindle positioning”
0127
Spindle positioning, setting the internal zero mark
(–> 5.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Integer16
immed.
By setting bit 0 to 1, the zero mark offset to the hardware zero mark is entered into P0128. After
this, 0 is written back into P0127.
Note:
refer under the index entry ”Spindle positioning”
A Lists
01.99
! 611ue diff !
04.05