Input/output terminals of the control board
6-475
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-43
Overview of the freely–parameterizable input terminals, continued
Terminals
Parameters
Drive A
Ef-
fec-
tive
Units
Max.
Standard
Min.
Name
No.
Drive B
I2.A
X451.9
I2.B
X452.9
0662
Function, in-
put terminal
I2.x
0
3
82
–
Im-
medi-
ately
I3.A
X451.10
I3.B
X452.10
0663
Function, in-
put terminal
I3.x
0
4
82
–
Im-
medi-
ately
–
–
–
–
Each input terminal can be assigned a function using these
parameters.
The function number from the list of input signals is entered
(refer to Chapter 6.4.3).
Note:
The status of the input terminals is displayed in P0678 for
diagnostic purposes (refer to Chapter 4.5).
6.4.3
List of input signals
Reader’s note
The drive receives the input signals, listed in the Tables 6-44 and 6-45
either from an input terminal or as control bit from PROFIBUS–DP.
All of the input signals can be found under the index entry ”Input
signal...”.
The following must be specified for each signal:
Fct. No.:
The function number is required to parameterize the input terminal
via the display and operator control unit.
Operating mode (P0700):
This specifies in which operating mode the signal is available
(x: Available, –: Not available).
n–set:
”Speed/torque setpoint” mode
pos: ”Positioning”
mode
PROFIBUS bit:
The bit name is required to control the signal via PROFIBUS–DP
(refer to Chapter 5.6.1).
Example: STW1.4
––> that means control word 1, bit 4