4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-175
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
For an incremental measuring system:
When the enable signals are present, a rotor position
rotor position identification was not successful,
the appropriate fault message is output. If the
causes of the fault are removed and the
fault message acknowledged, a new
identification attempt is made.
Zero marks?
No zero mark,
several zero marks
or distance–coded
reference marks
END
A zero mark is not selected
and an angular commutation
offset is
not transferred.
One zero mark
Set P1017 (”commissioning”)
to 1
Move the axis over the zero mark,
”jogging”
When the zero mark is passed,
the angular commutation
offset is automatically entered
into P1016
Alarm 799 is displayed
Save parameters and
carry–out a POWER–ON RESET
START
Hall sensor boxes
used?
No
Yes
At power–on, the rough synchronization
is retrieved from the
Hall sensor signals (C/D track)
Motor type
1FN1 or 1FN3?
1FN3
1FN1
Secondary conditions
fulfilled?
Yes
Mount Hall sensor
No
identification routine is immediately carried-out. If the
Fig. 4-12 Incremental measuring system
4 Commissioning
08.02