6
6.5
Input/output terminals for the optional TERMINAL module
6-527
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-50
Terminals and parameters for the optional TERMINAL module, continued
Terminals
Parameters
Drive A/B
Effec-
tive
Units
Max.
Stan-
dard
Min.
Name
No.
O9
X432.6
0689
Signaling function
output terminal O9
0
52
82
–
Immed.
O10
X432.7
0690
Signaling function
output terminal O10
0
53
82
–
Immed.
O11
X432.8
0691
Signaling function
output terminal O11
0
54
82
–
Immed.
–
–
0699
Inverting the
output terminal signals
0
0
FFF
hex
Immed.
2
0
= 1
2
1
= 2
2
2
= 4
2
3
= 8
P0699 =
0
5
0
6
hex
––> O8
O1.x
Example:
O10
O2.x
are output inverted
O0.x:
O1.x:
O2.x:
O3.x:
O4
O5
O6
O7
O8
O9
O10
O11
res.
res.
res.
res.
O0.x – O3.x are available
on the control board (refer
to Chapter 6.4.5)
–
–
0676
Assignment, inputs of the optional
TERMINAL module (from SW 4.1)
0
0
3
–
Immed.
–
–
0696
Assignment, outputs optional TERMI-
NAL module (from SW 4.1)
0
0
3
–
Immed.
Each input/output terminal can be assigned a function using these parameters.
Note:
Input terminals:
The function number from the list of input signals is entered (refer to Chapter 6.4.3).
The status of the input terminals is displayed in P0678 for diagnostic purposes (refer to Chapter 4.5).
Output terminals:
The function number from the list of output signals is entered (refer to Chapter 6.4.6).
The status of the output terminals is displayed in P0698 for diagnostics (refer to Chapter 4.5).
The signals of the output terminals can be output inverted (P0699).
Assignment of the terminals:
Before SW 4.1 the following applies:
All of the input/output terminals for the optional TERMINAL module are permanently assigned drive A.
From SW 4.1, the following applies:
For a double–axis module, the input/output terminals can be assigned, blockwise to either drive A or
B (P0676, P0696).
6 Description of the Functions
01.99
! not 611ue !
02.02