1
1.4
”SIMODRIVE 611 universal E” control board
1-57
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 1-8
Differences with respect to ”SIMODRIVE 611 universal”, continued
Differ-
ence
This should be observed for
SIMODRIVE 611 universal E
SIMODRIVE
Differ-
ence
This should be observed for
SIMODRIVE 611 universal E
611 universal E
611 universal
Angular
incre-
mental
encoder
interface
yes
no
Permissible settings, drive A
–
P0890 = 0
Encoder interface, inactive
–
P0890 = 4
Encoder interface, active
Permissible settings, drive B
–
P0890 = 0
Encoder interface, inactive
For all other parameter values, a fault is signaled.
The encoder interface is not suitable to connect a direct
measuring system for the following reasons:
The encoder signals are not evaluated in the drive.
Encoder
interface
(TTL en-
coder)
no
yes
The encoder in-
terface is used
to connect an
additional mea-
suring system
(TTL encoders,
encoder 3)
The encoder signals are not evaluated in the drive.
The drive transfers the information which is sensed
to a higher–level of control using the appropriate
process data.
The encoder interface is used for the ”Motion Control
with PROFIBUS–DP” function (clock cycle synchron-
ous operation, e.g. together with SINUMERIK 802D).
Note:
”Motion Control with PROFIBUS” function
––> refer to Chapter 5.8
Configuring telegrams
––> refer to Chapter 5.6.5
Encoder interface ––> refer to Chapter 5.6.4
Encoder
interface
Encoder 1
Encoder 1
Encoder 1
Motor measuring system (X411, X412)
Encoder 2
Direct measuring system (X412)
interface
(process
data)
Encoder 2
(from SW
3.3)
Encoder 2
(from SW
3.3)
Encoder 2
Direct measuring system (X412)
Encoder 3
TTL encoder (X472)
Description of the process data ––> refer to Chap. 5.6.4
no
Encoder 3
Description of the process data ––> refer to Chap. 5.6.4
Travers-
ing to
fixed
endstop
yes
from SW 3.3
no
This function is programmed using the FIXED END-
STOP command in the ”Positioning” mode.
The operating mode is not possible for SIMODRIVE 611
universal E ––> function not available
Axis cou-
plings
yes
from SW 3.3
no
This function can be used in either the ”External position
reference value” mode or ”Positioning”.
Operating modes are not possible for SIMODRIVE 611
universal E ––> function is not available