Parameterizing using the parameterizing and start–up tool SimoCom U
3-110
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
In order to go online with a drive via the PROFIBUS–DP fieldbus using
”SimoCom U”, the following prerequisites must be fulfilled:
1. ”SIMODRIVE 611 universal” control board from SW 3.1 with the fol-
lowing option module:
– Optional PROFIBUS–DP2 module (with ASIC DPC31 without
PLL)
Order No. (MLFB):
6SN1114–0NB00–0AA1
or
– Optional PROFIBUS–DP3 module (with ASIC DPC31 with PLL)
Order No. (MLFB):
6SN1114–0NB01–0AA0
2. ”SimoCom U” parameterizing and start–up tool from version 3.1
3. Communication boards, if connected via PROFIBUS
– CP 5511 (PROFIBUS coupling via PCMCIA card)
Design:
PCMCIA card, type 2 + adapter with 9–pin SUB–D socket con-
nector to connect to PROFIBUS.
Order No. (MLFB):
6GK1551–1AA00
or
– CP 5611 (PROFIBUS coupling through a short PCI card)
Design:
Short PCI card with 9–pin SUB–D socket to connect to
PROFIBUS.
Order No. (MLFB):
6GK1561–1AA00
– CP 5613 (PROFIBUS coupling via short PCI card)
(from SW 4.1)
Design:
Short PCI card with 9–pin SUB–D socket to connect to
PROFIBUS,
diagnostic LEDs,
PROFIBUS controller ASPC2 StepE
Order No. (MLFB):
6GK1561–3AA00
4. SIMATIC–CPU, if connected via an MPI interface
A routing–capable SIMATIC–CPU is required for a coupling via MPI
interface.
5. S7–DOS from V5.0
This software is supplied on the CD for ”SIMODRIVE 611 universal”
(refer to Chapter 1.3).
6. Connecting cable
– between CP 5511 or CP 5611 and the PROFIBUS fieldbus
or
– between the MPI interface from the PG and SIMATIC CPU
Requirements
3 Parameterizing the Board