6
6.4
Input/output terminals of the control board
6-477
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-44
Overview of the input signals, continued
Operating
mode
Signal name, description
PROFIBUS bit
pos
n–set
Fct. No.
Jogging 1 ON/jogging 1 OFF
62
–
x
STW1.8
Jogging 2 ON/jogging 2 OFF
63
–
x
STW1.9
Activate teach–in (edge) (from SW 4.1)
64
–
x
PosStw.6
Control requested/no control requested
–
x
x
STW1.10
Start referencing/cancel referencing
65
–
x
STW1.11
External block change (from SW 3.1)
67
–
x
STW1.13
Fixed end stop, sensor (from SW 3.3)
68
–
x
PosStw.3
Request passive referencing (from SW 5.1)
69
–
x
STW1.15
Tracking operation
70
–
x
PosStw.0
Set reference point
71
–
x
PosStw.1
Activates coupling (from SW 3.3)
72
–
x
PosStw.4
Activate the coupling via I0.x (from SW 3.3)
73
–
x
–
Setpoint setting, master drive (from SW 4.1)
74
–
x
QStw.0
Invert the angular incr. encoder input (from SW 3.5)
75
–
x
PosStw.7
Reference cams
78
–
x
PosStw.2
Equivalent zero mark
79
x
x
–
Flying measurement/length measurement (from SW
3.1)
80
x
–
–
Plus hardware limit switch (NC contact) (n–set from
SW 8.1)
81
x
x
–
Minus hardware limit switch (NC contact) (n–set
from SW 8.1)
82
x
x
–
Activate MDI (from SW 7.1)
83
–
x
SatzAnw.15
Activate angular incremental encoder, handwheel (from
SW 8.1)
84
–
x
SatzAnw.13
Angular incremental encoder handwheel evaluation, bit
0 (from SW 8.1)
85
–
x
SatzAnw.11
Angular incremental encoder handwheel evaluation, bit
1 (from SW 8.1)
86
–
x
SatzAnw.12
ON/OFF 1
–
x
x
STW1.0
Ramp–function generator start/ramp–function gen-
erator stop
–
x
–
STW1.5
Enable setpoint/inhibit setpoint
–
x
–
STW1.6
Activate function generator (edge) (from SW 8.1)
–
x
–
STW1.8
Acceleration time zero for controller enable (from
SW 3.1)
–
x
–
STW1.13
Motor changed over (from SW 2.4)
–
x
–
STW2.11
Master sign–of–life (from SW 3.1)
–
x
x
STW2.12
STW2.13
STW2.14
STW2.15
6 Description of the Functions
01.99
! 611ue diff !
08.01