Input/output terminals of the control board
6-498
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.4.4
Permanently–connected output terminals
Table 6-46
Permanently–connected output terminals
Terminals
Function
Description
Drive A
Drive B
X421
AS1
AS2
Checkback signal,
start inhibit
The relay contact (NC contact) pulls–in, if the enable voltage
is available at terminal 663 (module–specific pulse enable).
Note
Mode of operation, application purpose and additional information on
the ”safe start inhibit” is included in:
Reference:
/PJU/
SIMODRIVE 611,
Configuration Manual, Drive Converters
Chapter ”Start inhibit in the drive modules”
6.4.5
Freely–parameterizable digital output terminals
There are 4 freely–parameterizable output terminals for each axis.
A terminal is parameterized by entering the appropriate required func-
tion number into the assigned parameter.
Which function numbers are available? ––> Refer to Chapter 6.4.6
P0699 is used to define as to whether the output signal is output, in-
verted, or not inverted.
Notice
The terminals may only be parameterized when the drive pulses are
canceled.
Description