6
6.3
Axis couplings (from SW 3.3)
6-441
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
For a speed–synchronous coupling, the drive accelerates after the cou-
pling has been switched–in, with the acceleration in P0103, up to the
speed of the master drive.
The following error, that is automatically obtained when the slave drive
accelerates due to the different output velocities, is no longer reduced
to zero.
The position difference of the two drives is constant in the synchronous
phase.
t
v
v
LA
v
FA
Following error
v
FA
v
LA
Speed, master drive
v
FA
Speed setpoint, slave drive
Ramp–up
phase
Synchronous phase
Braking
phase
”Activate coupling”
Output signal
”in synchronism”
1
0
1
0
Fig. 6-33 Speed synchronism (P0410 = 1 or 3)
Reader’s note
The phases are described in Table 6-40.
Speed
synchronism
(P0410 = 1 or 3)
6 Description of the Functions