6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-411
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Note
Input errors when entering block information are displayed using the
appropriate error messages, for all traversing blocks after a traversing
block has started.
All of the parameters, which are used to program traversing blocks, are
shown in the following.
Table 6-38
Parameters used to program traversing blocks
No.
Name
Min.
Standard
Max.
Units
Effective
0079
Reformatting
the memory
0
0
1
–
Immedi-
ately
... the memory for the traversing blocks can be reformatted, i.e. re–assigned.
0
Inactive, initial status
0 –> 1
Memory is being reformatted
When reformatting, increasing block numbers are written into the blocks at the
beginning of the memory. Invalid blocks (block number – 1) are at the end of
the memory.
Note:
After reformatting has been completed, the parameter is automatically reset to 0.
Advantages of a reformatted memory:
When the blocks are displayed via SimoCom U or via the display unit on the front panel,
the blocks are located at the beginning of the memory and are sorted according to increas-
ing block numbers; there are no gaps.
P0080
P0081
P0088
before
reformatting
to
after
reformatting
–1
xxx
...
yyy
:0
20
xxx
...
yyy
:1
15
xxx
...
yyy
:3
–1
xxx
...
yyy
:2
–1
xxx
...
yyy
:63
...
...
...
...
–1
xxx
...
yyy
:2
20
xxx
...
yyy
:1
15
xxx
...
yyy
:0
–1
xxx
...
yyy
:3
–1
xxx
...
yyy
:63
...
...
...
...
Parameter
overview
6 Description of the Functions
01.99
! not 611ue !