5
5.6
Net data (PKW and PZD area)
5-219
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
From the perspective of the DP master, status words are actual values.
The ”DP slave 611U” indicates an image of the sent process data (sta-
tus words, actual values) in P1789:17 (sent process data, PROFIBUS).
Table 5-4
Overview of the status words (actual values)
Status word
Operating mode
Comment
Abbrevi-
ation
Meaning
Data
type
4)
Signal
num-
ber
1)
n–set
pos
ZSW1
Status word 1
U16
50002
x
–
ZSW1
Status word 1
U16
50002
–
x
ZSW2
Status word 2
U16
50004
x
x
NIST_A
Speed actual value, most signifi-
cant word (nist–h)
I16
50006
x
x
NIST_B
Speed actual value, most signifi-
cant and least significant word
(nist–(h+l))
I32
50008
x
x
from SW 3.1
G1_ZSW
Encoder 1, status word
2)
U16
50010
x
–
G1_XIST1
Encoder 1, pos. actual value 1
2)
U32
50011
x
–
from SW 3.1
G1_XIST2
Encoder 1, pos. actual value 2
2)
U32
50012
x
–
from SW 3.1
G2_ZSW
Encoder 2, status word
3)
U16
50014
x
–
G2_XIST1
Encoder 2, pos. actual value 1
3)
U32
50015
x
–
from SW 3.3
G2_XIST2
Encoder 2, pos. actual value 2
3)
U32
50016
x
–
from SW 3.3
G3_ZSW
Encoder 3, status word
2)
U16
50018
x
–
G3_XIST1
Encoder 3, pos. actual value 1
2)
U32
50019
x
–
from SW 3.1
G3_XIST2
Encoder 3, pos. actual value 2
2)
U32
50020
x
–
from SW 3.1
MeldW
Message word
U16
50102
x
x
ADU1
Analog input, terminal 56.x/14
I16
50104
x
x
ADU2
Analog input, terminal 24.x/20
I16
50106
x
x
DIG_IN
Digital inputs, terminals I0.x to
I3.x
U16
50108
x
x
from SW 3.1
Ausl
Utilization
U16
50110
x
x
Pwirk
Active power
U16
50112
x
x
Msoll
Smoothed torque setpoint
I16
50114
x
x
IqGl
Smoothed, torque–generating
current Iq
I16
50116
x
x
from SW 3.1
QZsw
Status word, slave–to–slave
communications
U16
50118
–
x
from SW 4.1
UZK1
DC link voltage
U16
50119
x
x
from SW 8.3
AktSatz
Currently selected block
U16
50202
x
x
(n–set
from SW 5.1)
PosZsw
Positioning status word
U16
50204
–
x
XistP
Position actual value (pos. mode)
I32
50206
–
x
from SW 3.1
Overview of the
status words
(actual values)
5 Communications via PROFIBUS DP
08.99
08.01
04.05