5
5.6
Net data (PKW and PZD area)
5-261
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-25
Parameters for configuring the process data, continued
No.
Effective
Units
Max.
Standard
Min.
Name
P0922 =
1
Standard telegram 1, n
set
interface 16 bit
NSOLL_A
PZD1
STW1
PZD2
NIST_A
PZD1
ZSW1
PZD2
Setpoint
Actual
point
P0915
:1
50001
P0915
:2
50005
P0916
:1
50002
P0916
:2
50006
P0922 =
2
Standard telegram 2, n
set
interface 32 bit without encoder
PZD1
STW1
ZSW2
PZD1
ZSW1
PZD 4
Setpoint
Actual
point
PZD 4
STW2
P0915
:1
50001
P0915
:4
50003
P0916
:1
50002
P0916
:4
50004
PZD2
PZD 3
NSOLL_B
P0915
:2
50007
P0915
:3
50007
PZD2
PZD 3
NIST_B
P0916
:2
50008
P0916
:3
50008
P0922 =
3
Standard telegram 3, n
set
interface 32 bit with encoder 1
PZD1
STW1
ZSW2
PZD1
ZSW1
PZD 4
Setpoint
Actual
point
PZD 4
STW2
PZD 5
G1_STW
PZD 5
G1_ZSW
PZD 6
PZD 7
PZD 8
PZD 9
G1_XIST2
P0915
:1
50001
P0915
:4
50003
P0915
:5
50009
P0916
:1
50002
P0916
:4
50004
P0916
:5
50010
P0916
:6
50011
P0916
:7
50011
P0916
:8
50012
P0916
:9
50012
PZD2
PZD 3
NSOLL_B
P0915
:2
50007
P0915
:3
50007
PZD2
PZD 3
NIST_B
P0916
:2
50008
P0916
:3
50008
G1_XIST1
This process data is associated with the encoder interface (refer to
Chapter 5.6.4)
5 Communications via PROFIBUS DP
08.99