A
A.3
List of motors
A-877
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following applies for two ”identical” linear motors connected in
parallel:
The value for the individual motor is handled, as specified in column
”2 (parallel)” thus obtaining the value for the parallel circuit.
Table A-9
Parameters for unlisted motors (SLM)
Parameters
No. of motors
No.
Name
Units
Value
1
2 (parallel)
1102
Motor code number
–
3999
–
–
1103
Rated motor current
A(rms)
I
0
2
I
0
1104
Maximum motor current
A(rms)
I
max
2
I
max
1113
Force constant
N/A
F
2
F
1114
Voltage constant
Vs/m
k
E
k
E
1115
Armature resistance
Ω
R
A
0.5
R
A
1116
Armature inductance
mH
L
A
0.5
L
A
1117
Motor weight
kg
m
M
2
m
M
1118
Motor standstill current
A(rms)
I
0
2
I
0
1146
Maximum motor velocity
m/min
v
max
v
max
1170
Pole pair width
mm
2
τ
p
2
τ
p
1180
Lower current limit, current controller
adaptation
%
%
%
1181
Upper current limit, current controller
adaptation
%
%
%
1182
Factor, current controller adaptation
%
%
%
1400
Rated motor velocity
m/min
v
0
v
0
!
Danger
It is only permissible to connect temperature sensor cables with PELV
or SELV voltage (refer to EN 60204–1 Chapter 6.4)
Parameters for
unlisted motors
(SLM)
A Lists
01.99