A
A.1
Parameter list
A-737
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0085:64 Command
Min
Standard
Max
Unit
Data type
Effective
1
1
10
–
Unsigned16
PrgE
Each traversing block must contain precisely one command for execution.
Value Command
1
POSITIONING
2
ENDLESSTRAVERSING_POS
3
ENDLESSTRAVERSING_NEG
4
WAIT
5
GOTO
6
SET_O
7
RESET_O
8
FIXED ENDSTOP (from SW 3.3)
9
COUPLING_ON (from SW 3.3)
10
COUPLING_OFF (from SW 3.3)
Depending on the command, additional block information is required in a traversing block.
Note:
refer to the index entry ”Traversing blocks” or ”Command-dependent block information”
0086:64 Command parameter
Min
Standard
Max
Unit
Data type
Effective
0
1
65535
–
Unsigned16
PrgE
... specifies the supplementary block information required for the following commands.
Command
Additional information
WAIT
Waiting time in ms
GOTO
Block number
SET_O
1, 2, 3: Set direct output 1, 2 or 3 (both signals)
RESET_O
1, 2, 3: Reset direct output 1, 2 or 3 (both signals)
FIXED ENDSTOP (from SW 3.3)
Clamping torque or clamping force
Rotary drive: 1 – 65 535 [0.01 Nm]
Linear drive: 1 – 65 535 [N]
Note:
refer to the index entry ”Traversing blocks” or ”Command-dependent block information”
A Lists
01.99
! 611ue diff !
04.05