5
5.6
Net data (PKW and PZD area)
5-256
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are available for the process data configuring:
Table 5-25
Parameters for configuring the process data
No.
Name
Min.
Standard
Max.
Units
Effective
0915:17
PZD setpoint assignment PROFIBUS
0
0
65 535
–
Immedi-
ately
... is used to assign the signals to the process data in the setpoint telegram.
Permissible signals for the setpoint direction (control words) are:
ID
Significance
Abbrev.
Length
Mode
Signals according to the PROFIdrive Profile
0
No signal
NIL
16 bit
50001
Control word 1
STW1
16 bit
50003
Control word 2
STW2
16 bit
50005
Speed setpoint A (nsoll–h)
NSOLL_A
16 bit
n–set
50007
Speed setpoint B (n–soll (h + l))
NSOLL_B
32 bit
n–set
50009
Encoder 1 control word
G1_STW
16 bit
n–set
50013
Encoder 2 control word (from SW 3.3)
G2_STW
16 bit
n–set
50017
Encoder 3 control word
G3_STW
16 bit
n–set
50025
System deviation (DSC) (from SW 4.1)
XERR
32 bit
n–set
50026
Pos. contr. gain factor (DSC) (from SW 4.1)
KPC
32 bit
n–set
Equipment–specific signals, especially for ”SIMODRIVE 611 universal”
50101
Torque reduction
MomRed
16 bit
50103
Analog output, terminals 75.x/15
DAU1
16 bit
50105
Analog output, terminals 16.x/15
DAU2
16 bit
50107
Digital outputs, terminals O0.x to O3.x
DIG_OUT
16 bit
50109
Target pos. for ”Spindle positioning” (from SW 5.1) XSP
32 bit
n–set
50111
Distributed inputs
DezEing
16 bit
50113
Torque setpoint external
MsollExt
16 bit
(read–in, subscriber) (from SW 4.1)
50117
Ctrl word slave–to–slave traffic (from SW 4.1)
QStw
16 bit
pos
50201
Block selection
SatzAnw
16 bit
50203
Position control word
PosStw
16 bit
pos
50205
Override
Over
16 bit
pos
50207
Ext. position reference value (from SW 4.1)
Xext
32 bit
pos
50209
Correction, ext. pos. ref. val. (from SW 4.1)
XcorExt
32 bit
pos
50221
MDI position (from SW 7.1)
MDIPos
32 bit
pos
50223
MDI velocity (from SW 7.1)
MDIVel
32 bit
pos
50225
MDI acceleration override (from SW 7.1)
MDIAcc
16 bit
pos
50227
MDI deceleration override (from SW 7.1)
MDIDec
16 bit
pos
50229
MDI mode (from SW 7.1)
MDIMode
16 bit
pos
Parameter
overview
5 Communications via PROFIBUS DP
08.99
02.03