5
5.6
Net data (PKW and PZD area)
5-252
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Bit 31
Encoder pulses
Fine information
11
0
Internal
multiplication
P1042 for G1_XIST2 (encoder 1)
P1044 for G2_XIST2 (encoder 2)
––> For reference mark or
function ”Flying measurement”
P1043 for G1_XIST2 (encoder 1)
P1045 for G2_XIST2 (encoder 2)
––> for read absolute value (EnDat encoder)
8
Standard
value
9
Fig. 5-18 Partitioning and settings for Gx_XIST2
Encoder pulses
– The following applies for encoders with sin/cos 1Vpp:
Encoder pulses = No. of sinusoidal signal periods
– The following applies for resolvers with 12–bit resolution:
Encoder pulses = 1024
No. of pole pairs of resolver
– The following applies for resolvers with 14–bit resolution:
Encoder pulses = 4096
No. of pole pairs of resolver
5 Communications via PROFIBUS DP
08.99
05.00
07.03