6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-355
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are supplied using this configuration:
P1027.4
= 1: Linear motor encoder
P1024
Grid divisions, linear measuring system
SIMODRIVE
611 universal
ÏÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏÏ
Î
Î
Slides
Primary section
Secondary section
Linear
measuring
system
Sensor head
Fig. 6-10 Linear axis with linear motor encoder
The following parameters are supplied using this configuration:
P1027.4
= 0: Rotary motor encoder
P1005
Encoder pulses per revolution
(only encoders with sin/cos 1Vpp)
P0237:8
Encoder revolutions
P0238:8
Load revolutions
SIMODRIVE
611 universal
Encoder
with sin/cos 1Vpp: P1005
or
resolver:
Pole pair No.
Encoder revolutions
Ü =
Load revolutions
P0237:8
P0238:8
=
Gear
n
Encoder
n
Load
Ü
P0237:8
P0238:8
Rotary table
or
chuck
Rotary motor encoder: P1027.4 = 0:
Fig. 6-11 Rotary axis with rotary motor encoder
A modular rotary axis is set via the following parameters:
P0241
Activates the modulo conversion, rotary axis
P0242
Modulo range, rotary axis
Linear axis with
linear
motor encoder
Rotary axis
with rotary
motor encoder
Rotary axis
without/with
modulo correction
(from SW 2.4)
6 Description of the Functions
01.99
! not 611ue !
04.99