System Control Registers
196
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
System Control and Interrupts
Table 1-66. Software Reset Control 3 (SRCR3) Register Field Descriptions
Bit
Field
Value
Description
31-26
Reserved
Reserved
25
CAN1
CAN1 S/W Reset Control
When this bit is set, CAN01 module is reset. All internal data is lost and the registers are returned
to their reset states. This bit must be manually cleared after being set.
24
CAN0
CAN0 S/W Reset Control
When this bit is set, CAN10 module is reset. All internal data is lost and the registers are returned
to their reset states. This bit must be manually cleared after being set.
23:1
Reserved
Reserved
0
UART4
UART4 S/W Reset Control
When this bit is set, UART4 module is reset. All internal data is lost and the registers are returned
to their reset states. This bit must be manually cleared after being set.