Registers
772
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
C28 Enhanced Pulse Width Modulator (ePWM) Module
Figure 7-125. Digital Compare Filter Window Register (DCFWINDOW)
15
8
Reserved
R-0
7
0
WINDOW
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 7-75. Digital Compare Filter Window Register (DCFWINDOW) Field Descriptions
Bit
Field
Value
Description
15-8
Reserved
Reserved
7-0
WINDOW
Blanking Window Width
00h
No blanking window is generated.
01-FFh
Specifies the width of the blanking window in TBCLK cycles. The blanking window begins
when the offset counter expires. When this occurs, the window counter is loaded and begins
to count down. If the blanking window is currently active and the offset counter expires, the
blanking window counter is restarted.
The blanking window can cross a PWM period boundary.
Figure 7-126. Digital Compare Filter Window Counter Register (DCFWINDOWCNT)
15
8
Reserved
R-0
7
0
WINDOWCNT
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 7-76. Digital Compare Filter Window Counter Register (DCFWINDOWCNT) Field Descriptions
Bit
Field
Value
Description
15-8
Reserved
Any writes to these bit(s) must always have a value of 0.
7-0
WINDOWCNT
00-FF
Blanking Window Counter
These 8 bits are read only and indicate the current value of the window counter. The counter
counts down to zero and then stops until it is re-loaded when the offset counter reaches zero
again.
Figure 7-127. Digital Compare A High Trip Input Select (DCAHTRIPSEL) (EALLOW-protected)
15
14
13
12
11
10
9
8
Reserved
TRIPIN15
TRIPIN14
Reserved
TRIPIN12
TRIPIN11
TRIPIN10
TRIPIN9
R-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
7
6
5
4
3
2
1
0
TRIPIN8
TRIPIN7
TRIPIN6
TRIPIN5
TRIPIN4
TRIPIN3
TRIPIN2
TRIPIN1
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset