Register Descriptions
1326
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
M3 Universal Serial Bus (USB) Controller
18.5.20 USB Full-Speed Last Transaction to End of Frame Timing Register (USBFSEOF),
offset 0x07D
USB full-speed last transaction to end of frame timing 8-bit configuration register (USBFSEOF) specifies
the minimum time gap allowed between the start of the last transaction and the EOF for full-speed
transactions.
Mode(s):
OTG A or Host
OTG B or Device
USBFSEOF is shown in
and described in
.
Figure 18-25. USB Full-Speed Last Transaction to End of Frame Timing Register (USBFSEOF)
7
0
FSEOFG
R/W-0
R/W-1
R/W-1
R/W-1
R/W-0
R/W-1
R/W-1
R/W-1
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 18-28. USB Full-Speed Last Transaction to End of Frame Timing Register
(USBFSEOF) Field Descriptions
Bit
Field
Reset
Description
7-0
FSEOFG
77h
The full-speed end-of-frame gap field is used during full-speed transactions to configure the gap
between the last transaction and the End-of-Frame (EOF), in units of 533.3 ns. The default corresponds
to 63.46
μ
s.
18.5.21 USB Low-Speed Last Transaction to End of Frame Timing Register (USBLSEOF),
offset 0x07E
The USB low-speed last transaction to end of frame timing 8-bit configuration register (USBLSEOF)
specifies the minimum time gap that is to be allowed between the start of the last transaction and the EOF
for low-speed transactions.
Mode(s):
OTG A or Host
OTG B or Device
USBLSEOF is shown in
and described in
.
Figure 18-26. USB Low-Speed Last Transaction to End of Frame Timing Register (USBLSEOF)
7
0
LSEOFG
R/W-0
R/W-1
R/W-1
R/W-1
R/W-0
R/W-0
R/W-1
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 18-29. USB Low-Speed Last Transaction to End of Frame Timing Register
(USBLSEOF) Field Descriptions
Bit
Field
Reset
Description
7-0
LSEOFG
72h
The low-speed end-of-frame gap field is used during low-speed transactions to set the gap between the
last transaction and the End-of-Frame (EOF), in units of 1.067
μ
s. The default corresponds to 121.6
μ