9.1List of parameters
9-29
No. Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
16
Torque saturation
error protection
frequency
time
0 to
30000
2
If torque saturated is continued
during a preset frequency, Err 16.1
"Torque saturation protection" will
be activated.
The number of times is counted up
every 0.25 ms. For example, when
30000 is set, Err16.1 occurs if the
torque saturation condition
continues for 7.5 seconds.
The count is cleared when the
torque saturation condition is
removed.
When the value set for Pr6.57 is
other than 0, the value set for Pr6.57
is enabled.
B
Position,
Velocity,
Full-closed
22
Communication
function extended
setup 1
-
-32768 to
32767
2
bit0 to 4:
For manufacturer’s use
All bits permanently set at
0.
R
All
bit5: 6080h/6880h(Max motor
speed) on csp mode (Amount
of change saturation function
of command position)
0: Invalid on csp
1: Valid on csp
bit6: Homing return speed limit
function enabled
0: Invalid
1: Valid
bit 7: In Z phase homing Over-travel
inhibit input setup
0: Invalid
1: Valid
bit 8 to 10:
For manufacturer’s use
All bits permanently
set at 0.
bit 11 to 15:
For manufacturer’s use
All bits permanently
set at
Set up the properly according to the
specifications of the host controller.
If the setting is not proper, the
operation is not be guaranteed.
23
Communication
function extended
setup 2
-
-32768 to
32767
2
bit0 to 13: For manufacturer's use
All bits permanently set
at 0.
B
All
bit14: Command positional
deviation
[Command unit] output
setting
0: Internal command
position (after filter)
[Command unit]
- Actual position
[command unit]
1: Internal command
position (before filter)
[Command unit]
- Actual position
[Command unit]
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...