9.1List of parameters
9-25
No. Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
64
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
65
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
66
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
67
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
68
For manufact
urer’s
use
-
-
2
Permanently set at 0.
-
-
-
69
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
70
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
71
3rd damping depth
-
0 to 1000 2
Set the damping depth for the 3rd
damping function.
B
Position,
Full-closed
72
4th damping depth
-
0 to 1000 2
Set the damping depth for the 4th
damping function.
B
Position,
Full-closed
73
Load estimation
filter
0.01 ms
0 to 2500 2
Set the filter time constant for load
estimation.
B
Position,
Velocity,
Full-closed
74
Torque
compensation
frequency 1
0.1 Hz
0 to 5000 2
Set the filter frequency 1 for speed
control output.
B
Position,
Velocity,
Full-closed
75
Torque
compensation
frequency 2
0.1 Hz
0 to 5000 2
Set the filter frequency 2 for speed
control output.
b
Position,
Velocity,
Full-closed
76
Load estimation
count
-
0 to 8
2
Set the number of times regarding
load estimation.
B
Position,
Velocity,
Full-closed
85
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
86
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
87
For manufacturer’s
use
-
-
4
Permanently set at 0.
-
-
-
88
Absolute encoder
multi-turn data
upper-limit value
-
0 to
65534
4
Set the upper-limit value for
absolute encoder multi-turn data
when Pr0.15 is set to 4.
If multi-turn data exceeds the set
value, the multi-turn data changes to
0 instead of the set value.
When the multi-turn data falls below
0, multi-turn data will change to the
set value.
When set to Pr0.15 = 0 or
2(absolute mode), the upper limit of
the absolute rotation data becomes
65535, regardless of this setting.
This setting will become invalid
when Pr0.15 is set to 1 or 3.
C
All
95
Over-load warning
detection level
%
0 to 114
2
Sets the threshold value for
detecting the warning as the
overload load factor increases.
Sets with the overload load factor.
If 0 is set, overload warning
detection is performed under
conventional conditions (85% of
overload protection level).
In addition, if other than "Pr6.96 <=
Pr6.95 < (Overload level)" is set,
overload warning detection is
performed under conventional
conditions (85% of overload level).
A
All
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...