Auto Tuning Functions
5-38
5.2.7 Damping control
This function reduces the vibration at the top or on whole of the equipment by removing the vibration
frequency components specified by the positional command. Up to 3 frequency settings, out of 4 settings
in total, can be used simultaneously.
Applicable range
Damping control is activated under the following conditions.
Conditions under which the damping control is activated:
Control Mode
Position control mode or Full-closed control mode.
Caution
This function does not work properly or no effect is obtained under the following conditions.
Conditions which obstruct the damping control effect:
Load
Vibration is triggered by other factors than command (such as disturbance).
Ratio of resonance frequency and anti-resonance frequency is large.
Vibration frequency is out of the range of 0.5 to 300.0 [Hz]
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...