Protective Functions
7-32
7.3 Warning function
The warning will be triggered before the protective function is activated, and you can check the conditions
such as overload beforehand.
One of the following warning modes can be selected through the setting of Pr 6.27 Warning latch state
setting: the warning non-latch mode in which the warning is automatically cleared 1 sec. after the cause of
warning is removed, and the warning latch mode in which the warning is kept issued even after the cause of
warning is removed. To clear the latched state, use the alarm clearing procedure described in previous alarm
section.
Note that the battery warning is latched by the encoder: after unlatching at the encoder, the warning is
cleared.
Relevant parameters
Relevant parameters
Class No.
Attribute
Title
Range
Unit Function
4
40
A
Selection of alarm
output 1
0 to 40
-
Select the type of warning issued as the warning output 1
(WARN1).
Setup value 0: ORed output of all warnings.
For 1 and subsequent see the table below."Warning
types"
4
41
A
Selection of alarm
output 2
0 to 40
-
Select the type of warning issued as the warning output 2
(WARN2)
Setup value 0: ORed output of all warnings.
For 1 and subsequent see the table below. "Warning
types"
6
27
C
Warning latch
state setup
0 to 3
-
Set the latching state of warning.
General warning and extended warning can be specified.
bit 0: Extended warning
0:unlatch
1:latch
bit 1: General warning
0:unlatch
1:latch
6
37
B
Oscillation
detecting level
0 to 1000
0.1%
Set the threshold of oscillation detection.
When torque vibration beyond this setting is detected, an
oscillation detection alarm is activated.
If the set value is 0, this function is disabled and the alarm
is not activated.
6
38
R
Alarm mask setup -32768 to
32767
-
Set the warning detection mask.
To disable detection of a warning, place 1 to the
corresponding bit.
6
39
C
Alarm mask setup
2
-32768 to
32767
-
6
95
A
Over-load warning
detection level
0 to 114
%
Sets the threshold value for detecting the warning as the
overload load factor increases.
Sets with the overload load factor.
If 0 is set, overload warning detection is performed under
conventional conditions (85% of overload protection
level).
In addition, if other than "Pr6.96 <= Pr6.95 < (Overload
protection level)" is set, overload warning detection is
performed under conventional conditions (85% of
overload protection level).
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...