Advanced Safety Functions
8-2
8.1 Advanced safety functions
This driver module supports 14 types of safety functions, and can achieve up to SIL3, PLe, and Cat4* for
Safety integrity level, Performance level, and Category.
* A test pulse needs to be used to satisfy Cat4.
Safety monitoring program can bemade by using the safety function setting software PANATERM for Safety.
This safety monitoring program can be used to construct safety input/output, safety functions, and so forth to
suit the customer’s environment.
Applicable range of functional safety
Safety functions
Safety level
・
Safety integrity level
・
Performance level
・
Category
14 functions
STO, SBC, SS1, SS2, SSM, SSR, SLS, SOS,
SLA, SAR, SLI, SDI, SLP, SCA
SIL3, PLe, Cat4 (Note 1) (Note 2)
SIL3, PLe, Cat3 (Note 2)
SIL2, PLd, Cat3
(Note 1) A test pulse needs to be used to satisfy Cat4.
(Note 2) Encoder duplication needs to be configured in order to satisfy SIL3, PLe, and Cat4, or SIL3, PLe, and Cat3.
At the time of shipment, the safety monitoring program is enabled only the driver module
(device) and the STO function with the fixed OFF state. If the advanced safety function is
not required, motor drive and EtherCAT communication can be used normally as is.
If the advanced safety functions is required, refer to this chapter and "PANATERM for
Safety Programming Manual (SX-DSV03508)" and "Safety Installation Manual
(SX-DSV03514)", create a safety monitoring program that corresponds to the customer's
configuration, and write it in the driver module.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...