11.4Basic functions
11-9
11.4.2 Regenerative control function
This section describes the parameters of the power supply module that are related to the regeneration
control function.
For details on the specifications of the regenerative resistor, refer to "REFERENCE SPECIFICATIONS
Power supply module section (SX-DSV03452)".
Relevant parameters
PSM
Pr.
Name
Setting
range
Shipping
setting
Unit
Content
00
Regenerative
operation setup
0 to 3
1
-
Sets up the regeneration operation.
0: To be used by the manufacturer (do not set up the value)
1: An external resistor is used to execute regenerative overload
protection.
2: An external resistor is used, but regenerative overload protection is not
executed.
3: Driver is used without regenerative resistor, and regenerative overload
protection is not executed.
01
Regenerative
resistor load
factor selection
0 to 4
0
-
Selects the operation method for the regenerative resistor load factor
when an external regenerative resistor is selected (PSM Pr.00 = 1, 2).
0: Regenerative overload protection is detected with the regenerative
resistor operation rate of 10%.
1 to 4: To be used by the manufacturer (do not set up the values)
11.4.3 Main power off detection function
This section describes the parameters that are related to main power off detection.
For specifications of the main power supply, refer to "REFERENCE SPECIFICATIONS Power supply
module section (SX-DSV03452)".
PSM
Pr.
Name
Setting
range
Shipping
setting
Unit
Content
02
Main power off
detection time
0 to 2000 70
ms
Sets up the main power off detection time.
Main power off is not detected if the setting value is set smaller than 20 or
is set to 2000.
03
Main power off
warning
detection time
0 to 2000 0
ms
Sets the main power off warning detection time.
The main power off warning is not detected when the setting value is
smaller than 10 or is set to 2000.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...