Application Functions
6-10
Slow stop operation : S-shape deceleration
S shape process at the time of slow stop operation can be made by setting Pr5.57.
Refer to the following figure to set Pr5.57.
* Velocity control command at the time of starting slow stop operation shall be calculated from the actual velocity.
Braking distance
When Pr 5.56 and Pr5.57 has been set, the braking distance under emergency stop will increase by
approximately the following formula. Please confirm its influence on the actual machine operations, when
using.
In case of linear deceleration (Pr5.57 = 0)
Linear decelerating time [s]
Linear deceleration brake distance [revolution]
For S-shape deceleration (Pr5.57
≠ 0)
S-shape deceleration braking distance [revolution]
The above formulae are braking distances for the velocity control command only and the
actual motor control delay has to be taken into account. Furthermore, in case the torque
command under deceleration is restricted by emergency stop torque stetting, the braking
distance will not be as per the formulae indicated above.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...