9.1List of parameters
9-27
No. Title
Unit Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
98
Function expansion
setup 4
-
-2147483648
to
2147483647
4
Sets various function in bit units:
R
All
-
bit0-2: For manufacture use.
Permanently set at 0.
bit3:
Effective bit setting of
Multi-turn data.
0:16bit
1: 9bit
bit4 to 7:
For manufacture use.
Permanently set at 0.
bit8:
Control mode switching
function expansion
0: Conventional specification
1: hm operation expansion
specification
bit9 to 19: For manufacture use.
Please set fixed to 0
bit20: Mechanical brake circuit
overload protection function
0: Valid1
1: Invalid
bit21 to 31: For manufacture use.
Permanently set at 0.
bit 0 is the least significant bit.
101 For manufa
cturer’s
use
-
-
2
Permanently set at 0.
-
-
-
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...