4.7Absolute setup
4-27
Battery refreshment of the absolute encoder with battery
If batteries (lithium-thionyl chloride battery) are not discharged for a long time, including long storage,
battery alarm may occur due to the phenomenon of transient voltage drop at the next discharge. In order
to prevent this, you can perform battery discharge treatment (refreshment).
Battery refreshment is performed by PANATERM for Multi(USB communication, EoE communication).
When battery refreshment is executed, battery warning may occur. In that case, clear the
battery warning.
Do not refresh the battery with a batteryless absolute encoder.
4.7.2 External scale
Under full-closed control, an absolute system that does not require return to origin action after power-up,
can be configured.
External scale absolute system configuration
Absolute system configuration using EtherCAT communication interface
(Example: with driver module 2-axes connection)
In the EtherCAT communication response (driver to host controller), the absolute data is transferred to
the host controller as the current position data.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...