7.4Setup of gain pre-adjustment protection
7-37
When Pr 5.20 = 0 (detection through command positional deviation)
Pr 0.14 (Setup of positional deviation excess) = Vc / Kp x (1.2 to 2.0)
Vc: maximum frequency of positional command pulse [pulse (command unit)/s]
Kp: position loop gain [1/s]
Factor in ( ) is margin to prevent frequent activation of excess positional deviation protection
When Pr 5.20 = 1 (detection through encoder positional deviation and full-closed position
deviational)
Pr 0.14 (Setup of positional deviation excess) = Ve / Kp x (1.2 to 2.0)
Ve: maximum operation frequency [pulse/s] in encoder unit or external scale unit
Kp: position loop gain [1/s]
Factor in ( ) is margin to prevent frequent activation of excess positional deviation protection
When switching position loop gain Kp, select the smallest value for calculation.
When switching from the velocity control to position control, position deviation correcting
function is used, which will increase calculation value and error. To cope with these
problems, increase the margin.
Setup of motor working range
During the position control or full-closed control(Not supported), this function detects the motor position
which exceeds the revolutions set to Pr 5.14 Motor working range setup, and issues Err 34.0 Software
limit protection.
For details, refer to "6.2 Motor working range setup function".
Hybrid deviation excess error protection setup
At the initial operation with full-closed control, operation failure may occur due to reverse connection of
external scale or wrong external scale division ratio.
To indicate this type of defect, Err25.0 “Hybrid deviation excess error protection” is issued when the
deviation of motor position (encoder unit) an
d load position (external scale unit) exceed Pr3.28 “Hybrid
deviation excess setup.”
For details, refer to "4.5.3 Setting of hybrid deviation excess".
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...