5.2Manual adjusting function
5-37
Notch width and depth
The width of the notch filter is the ratio of the width of
–3 dB attenuation frequency band with respect to
the notch frequency at its center when depth is 0, and the value is as shown in the table below.
The notch filter depth indicates I/O ratio where the input at the center frequency is completely shut with
setup value 0 but fully received with setup value 100. The table below shows this value in dB on the right.
Notch width
Notch depth
I/O ratio
[dB]
0
0.50
0
0.00
-
∞
1
0.59
1
0.01
-40.0
2
0.71
2
0.02
-34.0
3
0.84
3
0.03
-30.5
4
1.00
4
0.04
-28.0
5
1.19
5
0.05
-26.0
6
1.41
6
0.06
-24.4
7
1.68
7
0.07
-23.1
8
2.00
8
0.08
-21.9
9
2.38
9
0.09
-20.9
10
2.83
10
0.10
-20.0
11
3.36
15
0.15
-16.5
12
4.00
20
0.20
-14.0
13
4.76
25
0.25
-12.0
14
5.66
30
0.30
-10.5
15
6.73
35
0.35
-9.1
16
8.00
40
0.40
-8.0
17
9.51
45
0.45
-6.9
18
11.31
50
0.50
-6.0
19
13.45
60
0.60
-4.4
20
16.00
70
0.70
-3.1
80
0.80
-1.9
90
0.90
-0.9
100
1.00
0.0
Notch filter frequency response
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...